[Oct 21, 2021] Valid 300-615 Test Answers & 300-615 Exam PDF [Q32-Q56]

Share

[Oct 21, 2021] Valid 300-615 Test Answers & 300-615 Exam PDF

Valid CCNP Data Center 300-615 Dumps Ensure Your Passing


How to book the Cisco 300-615: Troubleshooting Cisco Data Center Infrastructure Exam

These are the following steps for registering for the 300-615 exam.

  • Step 1: Log into your account at Pearson VUE.
  • Step 2: Select Proctored Exams and enter the exam number, 300-615.
  • Step 3: Follow the prompts to register.

NEW QUESTION 32
A Cisco UCSB-Series Blade Server is configured to boot a VMwareESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected but the server fails to boot from the SAN. Which action reserves the problem?

  • A. Set the same WWNN pools for vHBA adaptor
  • B. Set the same WWPN pools for vHBA adapters
  • C. Set the boot LUN to the lowest LUN ID in the storage array
  • D. Set the boot LUN to the highest LUN ID in the storage array

Answer: A

 

NEW QUESTION 33
The Cisco Nexus switch is connected to a peer switch that is not running Cisco NX-OS. The switches are connected using port channel and are experiencing packet loss. Which action should be performed on the Cisco Nexus switch ports to resolve this issue?

  • A. Turn off lacp suspend-individual.
  • B. Turn off lacp graceful-convergence.
  • C. Turn on lacp suspend-individual.
  • D. Turn on lacp graceful-convergence.

Answer: B

Explanation:
Section: Network

 

NEW QUESTION 34

Refer to the exhibit. When an engineer inserts 8-Gb FC SFP port 15 on a Cisco UCS Fabric Interconnect, the port fails. What is a possible cause of the issue?

  • A. The polarity of the fiber cable is reversed.
  • B. Port 15 is configured as an Ethernet port.
  • C. Port 15 is missing a license.
  • D. Port 15 is configured for 4-Gb FC.

Answer: D

Explanation:
Section: Storage Network

 

NEW QUESTION 35
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.

Answer:

Explanation:

 

NEW QUESTION 36
An engineer troubleshoots a VXLAN EVPN data center. The applications in the data center fail to reach the DNS server that is located at IP 10.10.10.10. The engineer examines the BGP EVPN routing table and notes that the IP prefix route that covers the DNS server is missing. Which action resolves the issue?

  • A. Configure an IP ARP entry to represent [4]:[0300.0000.00fc.bd00.0309]:[32]:[10.10.10.10]/136 in the routing table.
  • B. Configure an IP ARP entry to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[32]:[10.10.10.10]/272 in the routing table.
  • C. Set the IP prefix route to represent [5]:[0]:[0]:[32]:[10.10.10.10]/224 in the routing table.
  • D. Set the IP prefix route to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[0]:[0.0.0.0]/216 in the routing table.

Answer: C

Explanation:
Section: Network

 

NEW QUESTION 37
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?

  • A. 1- Power off the server and disconnect the power cord
    2- Confirm that all cards are available
    3- Connect the power cord and power on the server
  • B. 1- Disconnect the power cord
    2- Confirm that all cards are properly seated
    3- Connect the power cord
  • C. 1- Disconnect the power cord
    2- Confirm that all cards are property seated
    3- Connect the power cord and power on the server
  • D. 1- Power off the server and disconnect the power cord
    2- Confirm that all cards are property seated
    3- Connect the power cord and power on the server

Answer: D

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pd

 

NEW QUESTION 38

Refer to the exhibit. Partial configuration from N9K-1 and N9K-2 is included. The client has two WANs connected.
* WAN-1 is for normal business-day activities.
* WAN-2 is for server backups during nonworking hours of 1:00 a.m. to 5:00 a.m. daily.
The client says that at the scheduled time for backup, the data center server failed to use the WAN-2 link to back up the servers to the cloud backup system. What is the solution to this problem?

  • A. The Cron entry must be configured without double quotes.
  • B. The applet called "Backup" must include an action to remove the current static route.
  • C. The event timer must be written in epoch time format.
  • D. The Cisco Nexus switch must be configured with one applet because a configuration with two applets will fail.

Answer: B

Explanation:
Section: Automation
Explanation

 

NEW QUESTION 39
A Cisco UCSB-Series Blade Server is configured to boot a VMwareESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected but the server fails to boot from the SAN. Which action reserves the problem?

  • A. Set the same WWNN pools for vHBA adaptor
  • B. Set the same WWPN pools for vHBA adapters
  • C. Set the boot LUN to the lowest LUN ID in the storage array
  • D. Set the boot LUN to the highest LUN ID in the storage array

Answer: B

 

NEW QUESTION 40
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.

Answer:

Explanation:

 

NEW QUESTION 41
After upgrading a client's fabric interconnect to the latest version, an engineer discovers that the appliance has lost its entire configuration. Which two locations should an engineer check to confirm that the appliance had backed up the configuration prior to the upgrade in order to retrieve the lost configuration? (Choose two.)

  • A. Service profiles page, InternalBackup stage
  • B. Equipment FSM page, PollInternalBackup stage
  • C. Admin page, InternalBackup stage.
  • D. Admin page, PollInternalBackup stage
  • E. Equipment FSM page, InternalBackup stage

Answer: D,E

 

NEW QUESTION 42
An engineer must configure Linux hosts that are deployed on Cisco UCS B-Series Servers to boot from SAN. The SAN boot policy is configured in Cisco UCS Manager, and the boot order is verified to be set as expected However, the Linux hosts fail to boot. Which action resolves the issue?

  • A. Delete and reconfigure the boot LUN
  • B. Remove all of the local storage that is installed
  • C. Remove all of the ISO images that are mounted as a virtual CD-ROM
  • D. Delete and reconfigure the pWWN of the SAN boot target

Answer: B

 

NEW QUESTION 43

Refer to the exhibit. An engineer is troubleshooting why user1, user2, and user3 from group STORAGE- ADMINISTRATOR in Microsoft Active Directory cannot log in to the Cisco MDS SSH CLI. Which action resolves the issue?

  • A. Include specific users into MDS role configuration.
  • B. Configure the role name to match the group name on Microsoft Active Directory.
  • C. Configure SSH logins on Cisco MDS switch.
  • D. Integrate Cisco MDS with Microsoft Active Directory.

Answer: B

Explanation:
Section: Storage Network
Explanation

 

NEW QUESTION 44
Refer to the exhibit.

After a failover occurs, which two actions must be performed on Switch-B to manually preempt the operational primary role back to Switch-A? (Choose two.)

  • A. Configure the local vPC role priority to have the same value as Switch-A.
  • B. Configure the local vPC role priority to have a lower value than Switch-A.
  • C. Configure the local vPC role priority to have a higher value than Switch-A.
  • D. Disable and then re-enable the vPC peer-keepalive link.
  • E. Disable and then re-enable the vPC peer link.

Answer: C,E

 

NEW QUESTION 45
Refer to the exhibit.

A network engineer traces the packet flow from the Veth991 of a blade server toward the core switch. The switch reports performance issues What is the role of the interface Eth1/7?

  • A. IOM host interface
  • B. server interface
  • C. fabric interconnect uplink interface
  • D. IOM network interface

Answer: C

Explanation:
Explanation
E1/7 is border interface, which is used as uplink. All other veth interfaces are SIF, which stands for Server Interface.

 

NEW QUESTION 46
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?

  • A. 1- Power off the server and disconnect the power cord
    2- Confirm that all cards are available
    3- Connect the power cord and power on the server
  • B. 1- Disconnect the power cord
    2- Confirm that all cards are properly seated
    3- Connect the power cord
  • C. 1- Disconnect the power cord
    2- Confirm that all cards are property seated
    3- Connect the power cord and power on the server
  • D. 1- Power off the server and disconnect the power cord
    2- Confirm that all cards are property seated
    3- Connect the power cord and power on the server

Answer: D

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pd

 

NEW QUESTION 47
Refer to the exhibit.

The EEM script overrides all events in the system policy. What should be added to the script to resolve the issue?

  • A. event statement
  • B. configure terminal action
  • C. event-default action statement
  • D. environment variable

Answer: A

 

NEW QUESTION 48
Drag and drop the commands from the left onto the correct categories on the right.

Answer:

Explanation:

 

NEW QUESTION 49
Refer to the exhibit.

The HSRP configuration in the exhibit fails to function. Which action resolves this issue?

  • A. Configure the same HSRP group on both devices.
  • B. Configure HSRP version 2.
  • C. Set the MTU to 1500 bytes.
  • D. Enable IP redirects.

Answer: D

 

NEW QUESTION 50

Refer to the exhibit. An engineer deploys a SAN environment with two interconnected Cisco MDS 9000 Series Switches. When the engineer attempts a zone merge, it fails with the error that is presented in the exhibit.
Which action resolves the issue?

  • A. Ensure that the zone members have different names.
  • B. Change the name of one of the zones to match the other zone set.
  • C. Import or export a zone set between the switches to synchronize the switches.
  • D. Set the distribute policy of the zone to full.

Answer: A

Explanation:
Section: Storage Network
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/ N5K_Troubleshooting_Guide/n5K_ts_sans.html

 

NEW QUESTION 51
Cisco Unified Computing System Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops.
Which action resolves the issue?

  • A. Change the PIN groups on the vHBAs.
  • B. Modify the FCoE VLAN.
  • C. Set the FCoE VLAN as the native VLAN on server uplinks.
  • D. Modify the VLAN assignment to vNICs.

Answer: D

Explanation:
Section: Compute Platforms

 

NEW QUESTION 52
An engineer discovers that an NPV/NPIV uplink experiences a heavy load and plans to add more uplinks. Which statement about what occurs when the new uplinks are added is true?

  • A. New and existing connections use the new uplinks automatically.
  • B. Paths must be defined before new connections can use the new uplinks.
  • C. All connections must be reset before the new uplinks can be used.
  • D. Only new connections use the new uplinks automatically.

Answer: A

 

NEW QUESTION 53
An engineer must upgrade all components in a Cisco UCS domain to the same package version, but the upgrade process fails to complete. Which set of Auto Install actions resolves the problem?

  • A. Install Hypervisor Firmware, then Install Infrastructure Firmware
  • B. Install infrastructure Firmware, then Install Hypervisor Firmware.
  • C. Install Server Firmware, then Install Infrastructure Firmware
  • D. Install Infrastructure Firmware, then Install Server Firmware.

Answer: D

Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-5/b_GUI_Firmware_Ma

 

NEW QUESTION 54
Refer to the exhibit.

An engineer deploys SAN environment with two interconnected Cisco MDS 9000 Series switches. When the engineer attempts a zone merge, it fails with the error that is presented in the exhibit. Which action resolves the issue?

  • A. Change the name of one of the zones to match the other zone set.
  • B. Ensure that the zone members have different names.
  • C. Import or export a zone set between the switches to synchronize the switches.
  • D. Set the distribute policy of the zone to full.

Answer: C

Explanation:
Explanation
https://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/troubleshooting/guide/ts_guide.pd

 

NEW QUESTION 55

Refer to the exhibit. The vPC between switch1 and switch2 does not work. Which two actions resolve the problem? (Choose two.)

  • A. Match the vPC domain ID between the two devices.
  • B. Configure the IP address on the interface.
  • C. Configure one of the switches as primary for the vPC.
  • D. Correct the configuration of the vPC peer link and the vPC peer keepalive.
  • E. Activate VLANs on the vPC.

Answer: A,E

Explanation:
Section: Network

 

NEW QUESTION 56
......


The Cisco 300-615 exam is the perfect option for those individuals who want to validate their skills in troubleshooting the data center along with its network, storage, automation, operations, and more. This is one of the concentration tests designed for earning the CCNP Data Center certification, which must be taken after the core exam, known as 350-601 DCCOR. For those students who pass only the 300-615 test, the vendor will grant the Cisco Certified Specialist – Data Center Operations certificate.

300-615 Dumps Real Exam Questions Test Engine Dumps Training: https://www.passtestking.com/Cisco/300-615-practice-exam-dumps.html

300-615 exam dumps and online Test Engine: https://drive.google.com/open?id=11YVSxttr2lkd_wjI0ckFFK2kZt66_V9i