
5V0-21.21 Free Update With 100% Exam Passing Guarantee [2021]
[Dec-2021] Verified VMware Exam Dumps with 5V0-21.21 Exam Study Guide
VMware 5V0-21.21 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
NEW QUESTION 15
During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.
Which two commands must be run to extend the time? (Choose two.)
- A. /etc/init.d/clomd restart
- B. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50
- C. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80
- D. /etc/init.d/vsanmgmtd restart
- E. /etc/init.d/vsanobserver restart
Answer: A,C
NEW QUESTION 16
An administrator is tasked with preparing for a Cross vCenter migration in a stretched vSAN cluster where the virtual machines migration will be orchestrated via VMware Site Recovery Manager.
Which action should the administrator take so the migration is successful?
- A. Enable vCenter Single Sign-On Enhanced Linked Mode
- B. Reconfigure vCenter HA Admission control
- C. Disable vSAN Deduplication and Compression
- D. Make sure that Witness traffic is on the management NIC.
Answer: A
NEW QUESTION 17
A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.
What will be the impact on the vSAN cluster?
- A. The performance will be degraded.
- B. The VMs will be in a suspended state.
- C. There will be no impact on performance.
- D. The VMs will no longer be accessible.
Answer: C
NEW QUESTION 18
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?
- A. SFTT = 0
- B. PFTT = 0
- C. SFTT = 1
- D. PFTT = 1
Answer: A
NEW QUESTION 19
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?
- A. Restore the communication with the KMS server, and re-establish the trust relationship.
- B. Manually replace the Host Encryption Key (HEK) of each affected host.
- C. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
- D. Replace the caching device in each affected disk group.
Answer: A
NEW QUESTION 20
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.
Which three prerequisites must be satisfied before completing the task? (Choose three.)
- A. Establish a trusted connection with the KMS
- B. Enable Data-In-Transit encryption first
- C. Verify if a role with privilege "Cryptographic operations.Migrate" is assigned
- D. Enable that the virtual machines are powered on
- E. Verify if a role with privilege "Cryptographic operations.Encrypt new" is assigned
- F. Create an encryption storage policy
Answer: A,D,E
NEW QUESTION 21
An architect is designing a vSAN cluster.
Which storage controller option will yield optimal performance?
- A. Enable battery write-back caching
- B. Hugh queue depth
- C. RAID 0
- D. Set caching to 50% read on the controller
Answer: C
NEW QUESTION 22
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)
- A. Choose the Allow reduced redundancy option.
- B. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
- C. Upgrade to VMware vCenter Server 7.0 U1.
- D. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
- E. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
- F. Disable vSAN Encryption before starting the upgrade process.
Answer: D
NEW QUESTION 23
An administrator is planning to deploy cloud-native workloads onto the vSAN Direct datastore.
Which storage policy structure rule is supported?
- A. Storage performance-based rules
- B. Tag-based placement rules
- C. vVOL storage rules
- D. Host-based rules
Answer: D
NEW QUESTION 24
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)
- A. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
- B. Replace the failed disk with a storage device that is identical in class and capacity.
- C. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
- D. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
- E. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.
- F. Put the affected vSAN host into maintenance mode to physically replace the storage device.
Answer: B,C,D
NEW QUESTION 25
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?
- A. vSAN network diagnostic mode is not enabled.
- B. vSAN performance service is turned off.
- C. vSAN proactive tests haven't been run yet.
- D. vSAN performance verbose mode is not enabled.
Answer: B
Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.
NEW QUESTION 26
A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.
Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)
- A. Place the host in maintenance mode with no data migration
- B. Place the host in maintenance mode with Full Data migration
- C. Remove from vSAN cluster
- D. Delete the disk group(s) on the legacy host
- E. Place the host in maintenance mode with Ensure Accessibility
- F. Disconnect from vCenter Server
Answer: B,C,D
NEW QUESTION 27
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
* 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
* De-duplication and Compression is enabled.
* vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)
- A. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.
- B. Update the existing Disk Group, and claim the newly installed drives for each node.
- C. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.
- D. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.
- E. Install an additional 3 x 1.8 TB SSDs per vSAN node.
Answer: C,E
NEW QUESTION 28
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?
- A. Obtain additional free capacity from the existing FC storage.
- B. Create an HCI Mesh using the first cluster's datastore.
- C. Create an HCI Mesh using the second cluster's datastore.
- D. Obtain additional free capacity from the existing NAS storage.
Answer: D
NEW QUESTION 29
An administrator of "vsan-prod" cluster noticed the witness components of VMs are flagged as absent after a failed attempt to replace the vSAN Witness Host.
Which action should the administrator take to resolve this issue?
- A. Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
- B. Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
- C. Upgrading the vSAN on-disk format
- D. Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod
Answer: B
NEW QUESTION 30
data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?
- A. Enable operations reserve.
A minimum cluster of 3 vSAN nodes. - B. Enable host build reserve.
A minimum cluster of 4 vSAN nodes. - C. Enable IOInsight Metrics.
A minimum cluster of 2 vSAN ROBO nodes. - D. Enable performance services.
A minimum cluster of 6 vSAN nodes.
Answer: B
NEW QUESTION 31
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system. The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?
- A. A 16GB multiple-level cell (MLC) SATADOM device must be used.
- B. A 4GB USB or SD device must be used.
- C. ESXi Hosts must boot from a PMEM device.
- D. A 16GB single-level cell (SLC) SATADOM device must be used.
Answer: A
NEW QUESTION 32
An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the "Full-data migration" option.
What will happen after this action is taken?
- A. The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
- B. The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.
- C. The host will enter in maintenance mode and only data with no redundancy will remain accessible.
- D. The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.
Answer: B
NEW QUESTION 33
......
Authentic Best resources for 5V0-21.21 Online Practice Exam: https://www.passtestking.com/VMware/5V0-21.21-practice-exam-dumps.html
5V0-21.21 Test Engine Practice Exam: https://drive.google.com/open?id=1qM7xgp8YQO_KTlROqUHZD_VcpVVhtOIL